The
Distillation Group, Inc. Home Services Newsletter Contact Distillation Technical Software Training Questions Links Search Navigation

WATER DAMAGE TO A REFINERY ATMOSPHERIC CRUDE FRACTIONATOR

Andrew W. Sloley

VECO USA, Inc. (current affiliation)
1313 Bay St
Bellingham, WA 98229 360-676-1500

Presented at the
The American Institute of Chemical Engineers Spring Meeting
15-18 March 1999

Abstract copyright Andrew W. Sloley
1999
All rights reserved

A case history of damage to a refinery atmospheric column caused by water feed to the tower is examined. Control system data as well as field data are shown. Due to unusual circumstances, the timing of the water incident could be determined accurately. Observed damage found when the tower was opened is shown. Specific comments are made by review of the observed damage. Many photographs of damage are shown along with a comparison of the impact on the different types of trays involved. Conclusions on mechanical reliability are reviewed.

7 pages.
Electronic version available in Adobe Acrobat PDF format file 079.PDF 222k.

Request paper 079.

*current affiliation

This page updated 22 January 2005